Turbo for High Temperature

Centrifugal Turbo for High Temperature Blower

Installation of the blower

CW

CCW

Reference

  1. Outlet of the blower can be changed in 30 degree interval depending on the purpose of using.
  2. Driving part of the blower can be changed to the other way, so direction of outlet can be changed as well. In this case, impeller must be replaced to the opposite direction(except Radial-type).
  3. Depending on the size of the product, impeller can be used as follows
    1) Lateral plate parallel type
    2) Lateral plate oblique type
    3) Radial type
  4. In the case of radial type, only fan can be replaced from existing product for transporting of grains, chemical granules and so on.

Dimensions (Unit: mm)

Blower for high temperature is 50mm longer in some part(C.L) of outline and the other size is the same as that of standard product, including air direction, air pressure.

* Outline is controlled in ∓5mm.
* For the improvement of performance, outline is subject to change without prior notice.

Specification of Impeller

터보형
레디알형
Specs(kW) Turbo impeller(steel) Radial impeller(AL)
Blade O.D(Ø) Height(mm) Shaft
diameter(Ø)
Blade O.D(Ø) Height(mm) Shaft
diameter(Ø)
0.75 327 64.2 19 300 45 19
1.5 327 80.5 24 327 68 24
2.2 340 110 24 350 72 24
3.7 380 125.5 28 380 78 28
Related Projects
Contact Us

We're not around right now. But you can send us an email and we'll get back to you, asap.

Not readable? Change text. captcha txt