Overview

Home / PRODUCTS / Motor / Overview

Temperature grade of rotating M/C

(KS 기준치)

 DIVISION OF
ROTATING M/C
E INSULATION B INSULATION F INSULATION
Thermometer method(K) resistance method
(K)
Thermometer method(K) resistance method
(K)
Thermometer method(K) resistance method
(K)
protection type closed type protection type closed type protection type closed type protection type closed type protection type closed type protection type closed type
Alternator Stator winding 65 70 75 75 70 75 80 80 80 85 100 100
adjacent part of iron core, winding wire 75 75 - - 80 80 - - 100 100 - -
bearing(self cooling type) When measuring on the surface 55℃ When measuring on the surface 55℃ When measuring on the surface 55℃

Three Phase Motor Torque Characteristic

(KS 기준치)

OUTPUT(kW) Ratio to rated torque
2P 4P 6P
minimum start
torque
pull-up
torque
stalling
torque
minimum start
torque
pull-up
torque
stalling
torque
minimum start
torque
pull-up
torque
stalling
torque
0.2 more than 1.9 more than 1.3 more than 2.0 more than 2.0 more than 1.4 more than 2.0 - - -
0.4 more than 1.9 more than 1.3 more than 2.0 more than 2.0 more than 1.4 more than 2.0 more than 1.7 more than 1.2 more than 1.7
0.75 more than 1.8 more than 1.2 more than 2.0 more than 1.9 more than 1.4 more than 2.0 more than 1.7 more than 1.2 more than 1.8
1.5 more than 1.8 more than 1.2 more than 2.0 more than 1.9 more than 1.3 more than 2.0 more than 1.6 more than 1.1 more than 1.9
2.2 more than 1.7 more than 1.1 more than 2.0 more than 1.8 more than 1.2 more than 2.0 more than 1.6 more than 1.1 more than 1.0
3.7 more than 1.6 more than 1.1 more than 2.0 more than 1.7 more than 1.2 more than 2.0 more than 1.5 more than 1.1 more than 1.9
5.5 more than 1.5 more than 1.0 more than 2.0 more than 1.6 more than 1.1 more than 2.0 more than 1.5 more than 1.1 more than 1.9
7.5 more than 1.5 more than 1.0 more than 2.0 more than 1.6 more than 1.1 more than 2.0 more than 1.5 more than 1.1 more than 1.8

Three Phase Induction Motor Decibel(dB)

(KS 기준치)

OUTPUT
(kW)
Protected Type Encapsulated Type
2P 4P 6P 2P 4P 6P
0.2 - - - 66below 59below -
0.4 - - - 69below 61below 60below
0.75 63below 58below 58below 73below 63below 61below
1.5 67below 58below 58below 75below 67below 61below
2.2 68below 62below 62below 77below 68below 63below
3.7 71below 65below 65below 80below 72below 65below
5.5 75below 67below 67below 83below 74below 68below
7.5 76below 69below 69below 84below 77below 70below

Classification by protection method of a induction motor

classification by protection method

Classification Grade Primary Classification Primary Classification General Classification
Protection Type for Human and Solid Body Orimary Classification Water Dripping
IP22 Structure Protects Human Body Such as Finger From Contacting to Spinning or Conductive Part of Motor Structure Does not Get any Influence by Water Dripping at Less Than 15Degree in Vertical Direction Dirp Proof Open Drip Proof  Type
IP23 Structure Does not Allow a Solid With Over 12mm in Diameter to Get Through Strictire Does not Get any Influence by Water Dripping at Less Than 60Degree in Vertical Direction Dirp Proof Open Drip Proof  Type
IP44 Structure Does not Allow a Solid Over 1mm in Diameter Such as Tools,Wire,Etc to Get Through in or Contact to Spinning or Conductive Part.However, Dainage and Vntilation Hle can be the Scondary Cassification Sructure. Structure Does not Get any Influence by Water Dripping in any Direction. Total Enclosed Type
IP54 Structure does not Allow any Object to Contact to Spinning or Conductive Part. Weather Poof
IP55 Structure That Blocks Dust and Ensures Normal Operation Even in Case of Dust Penetration. Structure Does not Get any Influence in Vertical Direction by Classification. Hose Proof

Protection type for the environment to be used

The protection type of the motor can be divided into a protection type(open) and a full-closed type, however, if equipment is not applied to the environment properly, which may cause a failure and shortening of the lifecycle. Therefore optimized protection type must be selected to meet the place to be used as follows.

Installation Place Environment Applied Protection Type
Indoor
General Place Open Drip Proof Type
Place With a Great Deal of Dust and Waste Open Drip Proof and Total Enclosed type
Place With Acid, Alkaline Liquid or Corrosive Gas Total Enclosed Increased Safety Explosion Proof Type and Total Enclosed Pressure Resistant Explosion Proof type
Place With Explosive or Combustible Gas or Liquid Dust Proof and Dust Eplosion Proof Type
Place limited by noise Open Drip Proof on Silencer Type
Place Where Large Amount of Water Flows Through Total Enclosed Type
Outdoor
General Place Total Enclosed Outdoor Type
Place With Explosive or Combustible Gas or Liquid Total Enclosed Outdoor Type, and Total Enclosed Outdoor Method Type
Place with acid, alkaline liquid or corrosive gas Total Enclosed Outdoor Type+Increased Safety Explosion Proof Type
Place With Explosive or Combustible Dust Total Enclosed Outdoor Type +Pressure resistant explosion proof type
Place Limited by Noise Total Enclosed Outdoor on Silencer Type
Place Where Large Amount of Water Flows Through Total Enclosed Outdoor Type
Being Used Under the Water Under Water Type